消防應急燈安裝在公共場所需要滿足哪些要求?
發布時間:2022-10-27 瀏覽:次 責任編輯:大成智慧
消(xiao)(xiao)(xiao)防(fang)(fang)(fang)(fang)應(ying)急(ji)(ji)(ji)燈(deng)廣泛安(an)(an)(an)裝在公共走廊和(he)消(xiao)(xiao)(xiao)防(fang)(fang)(fang)(fang)通道門上,是專業的(de)消(xiao)(xiao)(xiao)防(fang)(fang)(fang)(fang)安(an)(an)(an)全設(she)備。銷(xiao)售市(shi)場上的(de)許多消(xiao)(xiao)(xiao)防(fang)(fang)(fang)(fang)應(ying)急(ji)(ji)(ji)燈(deng)都是由消(xiao)(xiao)(xiao)防(fang)(fang)(fang)(fang)安(an)(an)(an)全單(dan)位的(de)消(xiao)(xiao)(xiao)防(fang)(fang)(fang)(fang)安(an)(an)(an)全單(dan)位生產的(de),具有(you)各(ge)種各(ge)樣的(de)效果(guo),但效果(guo)大(da)多是減弱的(de)。當(dang)消(xiao)(xiao)(xiao)防(fang)(fang)(fang)(fang)應(ying)急(ji)(ji)(ji)燈(deng)關閉時(shi),當(dang)有(you)來電(dian)(dian)時(shi),消(xiao)(xiao)(xiao)防(fang)(fang)(fang)(fang)應(ying)急(ji)(ji)(ji)燈(deng)將自(zi)動(dong)打(da)開和(he)關閉。消(xiao)(xiao)(xiao)防(fang)(fang)(fang)(fang)應(ying)急(ji)(ji)(ji)燈(deng)用作(zuo)備用照(zhao)明設(she)備。電(dian)(dian)池(chi)配(pei)有(you)一個電(dian)(dian)池(chi),在斷電(dian)(dian)時(shi)提供電(dian)(dian)能,在通電(dian)(dian)時(shi)給電(dian)(dian)池(chi)充電(dian)(dian)。
1、電(dian)池(chi)充(chong)電(dian)不(bu)成(cheng)功是因(yin)為可充(chong)電(dian)電(dian)池(chi)經(jing)常處于淺(qian)正(zheng)電(dian)荷和淺(qian)電(dian)狀態,并(bing)(bing)且(qie)電(dian)池(chi)電(dian)源(yuan)不(bu)能使用或失效,因(yin)此有(you)必要更換電(dian)池(chi)。當電(dian)池(chi)充(chong)電(dian)電(dian)源(yuan)電(dian)路Q2給電(dian)池(chi)充(chong)電(dian)時(shi),電(dian)流流量相(xiang)當大并(bing)(bing)且(qie)很容易(yi)破壞。
2、如果沒有交流電源(yuan),主電源(yuan)指示燈d14不亮,常(chang)見的問題(ti)是變壓(ya)器連接時間過長。
那么消(xiao)防應急燈安裝在公共場所需(xu)要滿足哪(na)些要求?下(xia)面大(da)成智慧消(xiao)防應急燈廠家的小編就來給大(da)家詳細的介紹一下(xia),具(ju)體有以下(xia)幾(ji)點:
1、消防(fang)應急(ji)(ji)燈(deng)和安(an)全疏散指示燈(deng)需要有兩個(ge)電(dian)(dian)(dian)源(yuan):正常電(dian)(dian)(dian)源(yuan)和應急(ji)(ji)備(bei)用電(dian)(dian)(dian)源(yuan)。應急(ji)(ji)備(bei)用電(dian)(dian)(dian)源(yuan)一般用作自供(gong)電(dian)(dian)(dian)和電(dian)(dian)(dian)池供(gong)電(dian)(dian)(dian),使用電(dian)(dian)(dian)池時連(lian)續(xu)通電(dian)(dian)(dian)時間不能少于200分(fen)鐘(zhong)。
2、應(ying)急照(zhao)明和安全(quan)指示燈(deng)應(ying)至少為(wei)0.5 lx,以完全(quan)照(zhao)亮人行(xing)道(dao)、樓梯和其他分散的(de)通(tong)道(dao)。消(xiao)(xiao)防(fang)(fang)控(kong)制室、消(xiao)(xiao)防(fang)(fang)泵房、獨立發電廠以及(ji)仍需留在(zai)火災中的(de)部件應(ying)配備總(zong)照(zhao)明。
3、安(an)全(quan)(quan)疏散標(biao)志應位于消(xiao)防出口頂部(bu)或逃(tao)生(sheng)通道墻的(de)拐(guai)角處及(ji)其(qi)下方1米處。標(biao)志間距不(bu)得(de)超過(guo)20m。必(bi)須(xu)為消(xiao)防應急燈和安(an)全(quan)(quan)疏散燈配備由玻(bo)璃和其(qi)他不(bu)燃材料制(zhi)成(cheng)的(de)保護罩。
4、逃生(sheng)應急(ji)燈必(bi)須(xu)安裝(zhuang)在墻(qiang)上或天(tian)花板(ban)上(消(xiao)防(fang)(fang)雙頭(tou)應急(ji)燈、消(xiao)防(fang)(fang)應急(ji)天(tian)花板(ban)燈、消(xiao)防(fang)(fang)應急(ji)燈/聚光燈等)。)。消(xiao)防(fang)(fang)應急(ji)照明位于消(xiao)防(fang)(fang)通(tong)道或消(xiao)防(fang)(fang)通(tong)道的兩側,距(ju)離(li)樓梯或樓梯頂(ding)部2.2米(mi)。長距(ju)離(li)分(fen)散路(lu)線應跟隨(sui)火(huo)勢。根(gen)據部門(men)的指示或實際使(shi)用場所的應急(ji)照明強度,提高照明密度并合理安裝(zhuang)。
5、緊(jin)急逃生指(zhi)示(shi)燈(deng)或安全(quan)出(chu)口指(zhi)示(shi)燈(deng)的裝置間隔不得超過20m。消防(fang)安全(quan)出(chu)口指(zhi)示(shi)燈(deng)的裝置標準、裝置高度(du)和光密度(du)應符合實際(ji)裝置環境和應急燈(deng)的實際(ji)裝置和用途。
以上內容就和大家分享到這里,內容僅供大家參考!如果想要了解更多關于消防應急燈的相關(guan)內(nei)容,請(qing)關(guan)注大成智慧消(xiao)防應急燈廠家網站(//longdayuan.com.cn/),我(wo)們會定(ding)期(qi)更新內(nei)容;如果想要了解消(xiao)防應急燈價格(ge)(ge)、消(xiao)防應急標志(zhi)燈價格(ge)(ge)、應急燈價格(ge)(ge)、照明(ming)燈價格(ge)(ge),歡迎來電咨詢!咨詢熱線(xian):133-4298-2185